Which VPS fits your Claude Code workload?

Test Claude Code on a representative checkout, then size the VPS from measured memory, disk, and runtime requirements. Compare qualifying quotes at your expected billable hours and track Claude usage separately.

Measure the test runner and agent together

Claude Code's setup guide lists 4 GB or more of RAM and an x64 or ARM64 processor. Use those as initial compatibility checks, then profile the repository where you expect to run it. On a dedicated pilot VPS, restore the same clean checkout before each cold test, use the same input data, and record peak system memory used, incremental workspace disk usage, test exit status, and elapsed time. Repeat with the number of simultaneous sessions you expect to support. An illustrative machine that uses 5.2 GiB during a cold build but 7.4 GiB with two concurrent test runs needs more than an 8 GiB quote if you reserve 1 GiB for spikes. Before selecting ARM64, repeat the test there to verify native dependencies and container images.

Advanced setup - Claude Code Docs

Rehearse a rebuild on the candidate runtime

Claude Code documents dev containers as a way to give engineers an identical environment. Use that property to run the same acceptance sequence on a plain VM and a container-based option. Start from a fresh instance, restore the repository, and rerun the tests after replacing the development environment. Check that the intended workspace output survives and that dependencies can still be fetched under the chosen network policy. If tests need sibling containers, include a benign service startup and health check so the comparison exercises the actual runtime dependency. Record minutes to rebuild and any operator intervention. An illustrative hourly machine at $0.10 per billed hour with $4 in persistent monthly charges equals a $24 flat quote at 200 hours. Use your actual quotes and include the cost of retained state.

Development containers - Claude Code Docs

Size for the busiest part of the run

Anthropic lists 4 GB or more of RAM and an x64 or ARM64 processor for Claude Code. For an illustrative sizing test, suppose a project has a 600 MB checkout, 2.2 GB of dependencies, and 1.6 GB of temporary build output. Those inputs account for 4.4 GB before logs, the runtime, or any operating system files on the same disk. A 4 GB workspace fails that budget even if the CLI starts successfully.

Compare Vultr Regular Cloud Compute, DigitalOcean Basic Regular CPU, and Hostinger KVM 1 using the same commit and project test sequence. Verify the exact regional offer, disk units and usable capacity, CPU allocation, and supported Linux image. Record peak memory, minimum free disk, and completion time. Use your own pass thresholds and rerun once with warm caches.

Advanced setup - Claude Code Docs

Sources