Incident Scenario Presets
Structural Geometry
Anchorage & Material State
Structural Stress Metrics
Velocity Pressure (q_z)
0.68 kPa
14.2 psf
Total Wind Force (F_w)
68.5 kN
Across 72.0 m² face
Overturning Moment
109.6 kNm
At facade bracket hinge
Tensile Bolt Pullout
41.2 kN/bolt
Capacity: 48.0 kN
Anchor Bolt Utilization Ratio (UR)
85.8%
Safe (<70%)
Yield Warning (70-100%)
Failure (>100%)
Drop Trajectory & Ground Hazard
⚠️ Impact Buffer Envelope
Estimated Fall Horizon: 14.6 m from wall
Freefall Impact Kinetic Energy: 44.1 kJ
Roadway and pedestrian sidewalk are inside direct collapse arc under 95 km/h crosswinds.
Forensic Audit Ledger
| Sign Self-Weight (Dead Load) | 2,880 kg (28.2 kN) |
| Effective Corroded Bolt Area | 235.6 mm² (-25%) |
| Shear Stress / Allowable | 92.4 / 160 MPa |
| Factor of Safety (FoS) | 1.17 (Critical) |
| Clearance Setback Required | 21.9 m (1.5x buffer) |